500 kVA Single-Phase Pole-Mount Transformer

Price range: $9,950.00 through $15,400.00

Single-Phase Pole-Mount Transformer, 15kV, 25kV, 35kV primary, 240V, 600V secondary. Aluminum windings, mineral oil, ONAN cooled, built to ANSI/IEEE C57.12 and DOE 2016 efficiency. 56 voltage configurations available.

Lead time: As little as 10 weeks. Copper windings and natural ester fluid available on request.

Contact Us
SKU: BPS-1PH-PM-500K Category:

The 500 kVA single-phase pole-mount distribution transformer is an overhead unit built for utility and rural distribution service. It hangs from a single pole or crossarm bracket and steps medium-voltage primary down to a 277 or 480 V secondary. At 500 kVA this is a heavy overhead unit. Confirm pole and crossarm capacity before specifying – ratings above 167 kVA are frequently supplied pad-mounted or platform-mounted instead.

Specifications

Rating 500 kVA
Phase Single phase
Primary voltage class 15kV / 25kV / 35kV
Secondary voltage class 240V / 600V
Basic insulation level (BIL) 95 kV / 125 kV / 150 kV
Frequency 60 Hz
Temperature rise 65 °C
Winding material Aluminum
Insulating fluid Mineral oil, Type I
Cooling class ONAN
Taps Plus/minus 2 x 2.5% full-capacity below and above nominal
Enclosure Munsell Green 7GY3.29/1.5, tamper-resistant
Feed configuration Per application
Standards ANSI/IEEE C57.12, NEMA, DOE 2016 efficiency
Lead time As little as 10 weeks

Full-load current

Rated secondary current for a 500 kVA unit at each available secondary voltage. Use these figures for conductor, breaker and bus sizing.

Secondary voltage Full-load current
120/240 2,083 A
240/480 1,042 A
277 1,805 A
480 1,042 A

Rated primary current at each available primary voltage:

Primary voltage Full-load current
2400 208 A
4160GrdY/2400 208 A
4800 104 A
7200 69 A
7620 66 A
12000 42 A
12470GrdY/7200 69 A
13200GrdY/7620 66 A
13800GrdY/7970 63 A
14400 35 A
19920 25 A
22900GrdY/13200 38 A
24940GrdY/14400 35 A
34500GrdY/19920 25 A

Typical applications

  • Overhead utility distribution on heavy-load feeders
  • Large single-phase commercial services
  • Multi-unit residential
  • Industrial single-phase process loads

Construction

Standard construction is aluminum windings in a sealed tank with mineral oil, ONAN cooled, 65 °C rise. The tank is welded and finished in Munsell Green 7GY3.29/1.5. A four-position no-load tap changer provides plus and minus two 2.5% full-capacity taps. Copper windings and natural ester fluid are available on request.

Standards and compliance

  • Built to ANSI/IEEE C57.12 and applicable NEMA standards
  • Meets DOE 2016 efficiency requirements
  • Factory test report supplied with every unit
  • Manufactured and supported by Bear Power Solutions, Brandon, Mississippi

Frequently asked questions

What voltages is the 500 kVA available in?

The 500 kVA is available with 15kV / 25kV / 35kV primary and 240V / 600V secondary. That is 56 configurations in total. Every voltage inside a class carries the same price and the same basic insulation level.

What is the lead time on a 500 kVA?

Lead times start at 10 weeks from order confirmation, depending on configuration and current factory loading. Non-standard voltages, accessories, custom enclosure work and non-standard fluid or winding material extend that. Confirm the delivery date with Bear Power Solutions before committing to a project schedule.

Can this transformer be pad-mounted instead of pole-mounted?

Bear Power Solutions supplies equivalent ratings in pad-mount configuration. Pole-mount units above 167 kVA are heavy enough that pole and crossarm capacity should be verified, and larger ratings are commonly supplied pad-mounted or platform-mounted instead.

Can the 500 kVA be supplied with copper windings or natural ester fluid?

Standard catalog construction is aluminum windings with mineral oil. Copper windings and natural ester fluid are available on request. Both affect price and lead time, so request a quotation for a non-standard build.

What standards does the 500 kVA meet?

Units are built to ANSI/IEEE C57.12 and applicable NEMA standards, and meet DOE 2016 efficiency requirements. Factory test reports are provided with every unit.

Sizing the 500 kVA

At its lowest available secondary voltage the 500 kVA draws 2,083 A at full load; at its highest it draws 1,042 A. That spread is what makes secondary voltage selection an installation-cost decision as much as an electrical one – the higher voltage cuts conductor size for the same delivered power.

Secondary current at this rating is high enough that parallel conductor runs or busway are normally required on the low-voltage side. Confirm the secondary termination arrangement and available bus space before ordering.

Request a quote

For a firm price on a 500 kVA in a specific voltage configuration, or for a non-standard build with copper windings, natural ester fluid or custom accessories, send the details below and Bear Power Solutions will respond with a written quotation.