750 kVA Substation Transformer

Price range: $22,800.00 through $36,650.00

Substation Transformer, 15kV, 25kV, 35kV primary, 4160V, 480V, 12470V, 24940V secondary. Aluminum windings, mineral oil, ONAN cooled, built to ANSI/IEEE C57.12 and DOE 2016 efficiency. 44 voltage configurations available.

Lead time: 12–16 weeks. Copper windings and natural ester fluid available on request.

- +
Contact Us
SKU: BPS-SUB-750K Category:
  • UL Listed options available
  • B.A.B.A.-compliant options available
  • Factory test report with every unit
Ordering online? Stock moves fast, so call 601-912-3512 or email sales@bearpowersolutions.com to confirm availability before you check out. If a unit has sold, we’ll quote a build slot and confirm the lead time in writing.

The 750 kVA substation transformer is built for primary distribution service, stepping medium- or high-voltage supply down to a distribution or utilization voltage. It is supplied with throat or bus connections for integration into a switchgear lineup. At 750 kVA it functions as a small unit substation for industrial plants and campus distribution.

Specifications

Rating 750 kVA
Phase Three phase
Primary voltage class 15kV / 25kV / 35kV
Secondary voltage class 4160V / 480V / 12470V / 24940V
Basic insulation level (BIL) 95 kV / 125 kV / 150 kV
Frequency 60 Hz
Temperature rise 65 °C
Winding material Aluminum
Insulating fluid Mineral oil, Type I
Cooling class ONAN
Taps Plus/minus 2 x 2.5% full-capacity below and above nominal
Enclosure ANSI 70 gray
Feed configuration Per application
Standards ANSI/IEEE C57.12, NEMA, DOE 2016 efficiency
Lead time 12–16 weeks

Full-load current

Rated secondary current for a 750 kVA unit at each available secondary voltage. Use these figures for conductor, breaker and bus sizing.

Secondary voltage Full-load current
4160Y/2400 104 A
480Y/277 902 A
12470Y/7200 35 A
13200Y/7620 33 A
13800 Delta 31 A
24940Y/14400 17 A

Rated primary current at each available primary voltage:

Primary voltage Full-load current
2400 Delta 180 A
4160 Delta 104 A
4160Y/2400 104 A
4800 Delta 90 A
7200 Delta 60 A
12000 Delta 36 A
12470Y/7200 35 A
13200 Delta 33 A
13200Y/7620 33 A
13800 Delta 31 A
13800Y/7970 31 A
22900Y/13200 19 A
24940Y/14400 17 A
34500 Delta 13 A
34500Y/19920 13 A

Typical applications

  • Small utility distribution substations
  • Renewable collection systems
  • Industrial plant primary supply
  • Campus and district distribution

Construction

Standard construction is aluminum windings in a sealed tank with mineral oil, ONAN cooled, 65 °C rise. The tank is welded and finished in ANSI 70 gray. A five-position no-load tap changer provides plus and minus two 2.5% full-capacity taps. Copper windings and natural ester fluid are available on request.

Standards and compliance

  • Built to ANSI/IEEE C57.12 and applicable NEMA standards
  • Meets DOE 2016 efficiency requirements
  • Factory test report supplied with every unit
  • Supplied and supported by Bear Power Solutions, Jackson, Mississippi

Frequently asked questions

What voltages is the 750 kVA available in?

The 750 kVA is available with 15kV / 25kV / 35kV primary and 4160V / 480V / 12470V / 24940V secondary. That is 44 configurations in total. Every voltage inside a class carries the same price and the same basic insulation level.

What is the lead time on a 750 kVA?

Lead times are 12–16 weeks from order confirmation, depending on configuration and current factory loading. Non-standard voltages, accessories, custom enclosure work and non-standard fluid or winding material extend that. Confirm the delivery date with Bear Power Solutions before committing to a project schedule.

Can this be supplied with a switchgear throat connection?

Yes. Substation transformers are commonly supplied with primary and secondary throat or bus connections for direct integration into a switchgear lineup. Specify the mating arrangement at time of quotation.

Can the 750 kVA be supplied with copper windings or natural ester fluid?

Standard catalog construction is aluminum windings with mineral oil. Copper windings and natural ester fluid are available on request. Both affect price and lead time, so request a quotation for a non-standard build.

What standards does the 750 kVA meet?

Units are built to ANSI/IEEE C57.12 and applicable NEMA standards, and meet DOE 2016 efficiency requirements. Factory test reports are provided with every unit.

Sizing the 750 kVA

At its lowest available secondary voltage the 750 kVA draws 902 A at full load; at its highest it draws 17 A. That spread is what makes secondary voltage selection an installation-cost decision as much as an electrical one – the higher voltage cuts conductor size for the same delivered power.

Secondary current at this rating is high enough that parallel conductor runs or busway are normally required on the low-voltage side. Confirm the secondary termination arrangement and available bus space before ordering.

Request a quote

For a firm price on a 750 kVA in a specific voltage configuration, or for a non-standard build with copper windings, natural ester fluid or custom accessories, send the details below and Bear Power Solutions will respond with a written quotation.

Weeks: 0
How quick do you need this Transformer(s)?
Primary Voltage

12000 Delta, 12470Y/7200, 13200 Delta, 13200Y/7620, 13800 Delta, 13800Y/7970, 22900Y/13200, 2400 Delta, 24940Y/14400, 34500 Delta, 34500Y/19920, 4160 Delta, 4160Y/2400, 4800 Delta, 7200 Delta

Secondary Voltage

12470Y/7200, 13200Y/7620, 13800 Delta, 24940Y/14400, 4160Y/2400, 480Y/277

// Request a quote

Firm price.
Written quote.

Tell us the kVA, primary and secondary voltage, quantity and where it’s going. We’ll come back with price, lead time and freight in writing. Copper windings, natural ester fluid and custom accessories are quoted to spec.

Facilities
About 25,000 sq ft across two locations
Lynch Street
5570 John R Lynch St., Jackson, MS · 17,000+ sq ft for distribution, assembly and transformer oil
Compliance
UL Listed options available · B.A.B.A.-compliant options available
// Trusted by
  • Supermicro logo
  • Flex logo
  • Memphis Light, Gas and Water (MLGW) logo
  • City of Fort Collins logo
  • City Utilities logo
  • Athens Utilities Board logo
  • TCEC logo
  • ALLETE Clean Energy logo
  • Entegrity logo
  • ASRC Federal logo
  • Lockheed Martin logo
  • DAVIS-MONTHANAir Force Base
  • FAIRCHILDAir Force Base
  • Oklahoma City University logo
  • Chicago Housing Authority logo
Shopping Cart