200 MVA Power Transformer

Price range: $2,609,500.00 through $5,829,000.00

Power Transformer, 115kV, 138kV, 161kV, 230kV, 69kV primary, 24940V, 34500V secondary. Aluminum windings, mineral oil, ONAN cooled, built to ANSI/IEEE C57.12 and DOE 2016 efficiency. 10 voltage configurations available.

Lead time: As little as 10 weeks. Copper windings and STRATA X3 natural ester available on request.

Contact Us
SKU: BPS-PWR-200M Category:

The 200 MVA power transformer is transmission-class equipment for bulk supply, generation step-up and utility substation service. It is supplied with radiator banks, high-voltage bushings and the gauges, relays and protection specified for the application. At 200 MVA this is transmission-class equipment supplied through contract manufacture. Lead times are long and every unit is engineered to the specific application.

Specifications

Rating 200 MVA
Phase Three phase
Primary voltage class 115kV / 138kV / 161kV / 230kV / 69kV
Secondary voltage class 24940V / 34500V
Basic insulation level (BIL) 550 kV / 650 kV / 750 kV / 900 kV / 350 kV
Frequency 60 Hz
Temperature rise 65 °C
Winding material Aluminum
Insulating fluid Mineral oil, Type I
Cooling class ONAN
Taps Plus/minus 2 x 2.5% full-capacity below and above nominal
Enclosure Munsell Green 7GY3.29/1.5, tamper-resistant
Feed configuration Per application
Standards ANSI/IEEE C57.12, NEMA, DOE 2016 efficiency
Lead time As little as 10 weeks

Available voltage configurations

The 200 MVA is offered in 10 primary and secondary voltage combinations. Price is set by voltage class, so every voltage within a class carries the same price – a 12470Y/7200 primary and a 13200Y/7620 primary are both 15 kV class and cost the same.

Primary voltages available:

  • 115kV class — 115000 GrdY
  • 138kV class — 138000 GrdY
  • 161kV class — 161000 GrdY
  • 230kV class — 230000 GrdY
  • 69kV class — 69000 Delta

Secondary voltages available:

  • 24940V class — 24940Y/14400
  • 34500V class — 34500Y/19920

Full-load current

Rated secondary current for a 200 MVA unit at each available secondary voltage. Use these figures for conductor, breaker and bus sizing.

Secondary voltage Full-load current
24940Y/14400 4,630 A
34500Y/19920 3,347 A

Rated primary current at each available primary voltage:

Primary voltage Full-load current
115000 GrdY 1,004 A
138000 GrdY 837 A
161000 GrdY 717 A
230000 GrdY 502 A
69000 Delta 1,673 A

Typical applications

  • Generation step-up for utility-scale plants
  • Bulk power supply
  • Interconnection of large generation assets
  • Transmission substation service

Construction

Standard construction is aluminum windings in a sealed tank with mineral oil, ONAN cooled, 65 °C rise. The tank is welded and finished in Munsell Green 7GY3.29/1.5. A four-position no-load tap changer provides plus and minus two 2.5% full-capacity taps. Copper windings and natural ester fluid, including STRATA X3, are available on request.

Standards and compliance

  • Built to ANSI/IEEE C57.12 and applicable NEMA standards
  • Meets DOE 2016 efficiency requirements
  • Factory test report supplied with every unit
  • Manufactured and supported by Bear Power Solutions, Brandon, Mississippi

Frequently asked questions

What voltages is the 200 MVA available in?

The 200 MVA is available with 115kV / 138kV / 161kV / 230kV / 69kV primary and 24940V / 34500V secondary. That is 10 configurations in total. Every voltage inside a class carries the same price and the same basic insulation level.

What is the lead time on a 200 MVA?

Lead times start at 10 weeks from order confirmation, depending on configuration and current factory loading. Non-standard voltages, accessories, custom enclosure work and non-standard fluid or winding material extend that. Confirm the delivery date with Bear Power Solutions before committing to a project schedule.

How is a power transformer of this size delivered and installed?

Units at this rating ship by specialized heavy haul, frequently with radiators, conservator and bushings removed and shipped separately. Site assembly, oil processing and field testing are required before energization. Delivery logistics should be planned alongside the order.

Can the 200 MVA be supplied with copper windings or natural ester fluid?

Standard catalog construction is aluminum windings with mineral oil. Copper windings and natural ester fluid – including STRATA X3, Bear Power Solutions’ own Type II natural ester – are available on request. Both affect price and lead time, so request a quotation for a non-standard build.

What standards does the 200 MVA meet?

Units are built to ANSI/IEEE C57.12 and applicable NEMA standards, and meet DOE 2016 efficiency requirements. Factory test reports are provided with every unit.

Sizing the 200 MVA

At its lowest available secondary voltage the 200 MVA draws 4,630 A at full load; at its highest it draws 3,347 A. That spread is what makes secondary voltage selection an installation-cost decision as much as an electrical one – the higher voltage cuts conductor size for the same delivered power.

Secondary current at this rating is high enough that parallel conductor runs or busway are normally required on the low-voltage side. Confirm the secondary termination arrangement and available bus space before ordering.

Choosing between 200 MVA and adjacent ratings

Bear Power Solutions also builds the 150 MVA below it in this family. If your load is comfortably under the 200 MVA figure, the 150 MVA carries lower no-load losses and a lower purchase price. Request a quote below with your actual load data and Bear Power Solutions will recommend a rating.

Request a quote

For a firm price on a 200 MVA in a specific voltage configuration, or for a non-standard build with copper windings, natural ester fluid or custom accessories, send the details below and Bear Power Solutions will respond with a written quotation.

Weeks: 0
How quick do you need this Transformer(s)?
Weight 420700 lbs
Primary Voltage

115000 GrdY, 138000 GrdY, 161000 GrdY, 230000 GrdY, 69000 Delta

Secondary Voltage

24940Y/14400, 34500Y/19920

Shopping Cart