300 kVA Three-Phase Pad-Mount Transformer

Price range: $22,641.15 through $37,235.00

Three-Phase Pad-Mount Transformer, 15kV, 25kV, 35kV primary, 240V, 600V secondary. Aluminum windings, mineral oil, ONAN cooled, built to ANSI/IEEE C57.12 and DOE 2016 efficiency. 105 voltage configurations available.

Lead time: As little as 10 weeks. Copper windings and natural ester fluid available on request.

Contact Us
SKU: BPS-3PH-PAD-300K Category:

The 300 kVA three-phase pad-mount transformer is a compartmental, dead-front distribution unit for commercial and industrial service. High- and low-voltage compartments sit side by side behind lockable steel doors, with underground cable entry through the base. At 300 kVA it suits retail, restaurant, small manufacturing and EV charging installations where a compact footprint matters.

Specifications

Rating 300 kVA
Phase Three phase
Primary voltage class 15kV / 25kV / 35kV
Secondary voltage class 240V / 600V
Basic insulation level (BIL) 95 kV / 125 kV / 150 kV
Frequency 60 Hz
Temperature rise 65 °C
Winding material Aluminum
Insulating fluid Mineral oil, Type I
Cooling class ONAN
Taps Plus/minus 2 x 2.5% full-capacity below and above nominal
Enclosure Munsell Green 7GY3.29/1.5, tamper-resistant
Feed configuration Radial feed, dead front
Standards ANSI/IEEE C57.12, NEMA, DOE 2016 efficiency
Lead time As little as 10 weeks

Full-load current

Rated secondary current for a 300 kVA unit at each available secondary voltage. Use these figures for conductor, breaker and bus sizing.

Secondary voltage Full-load current
208Y/120 833 A
240 Delta 722 A
240/120 Delta 722 A
415Y/240 417 A
480 Delta 361 A
480Y/277 361 A
600Y/347 289 A

Rated primary current at each available primary voltage:

Primary voltage Full-load current
2400 Delta 72 A
4160 Delta 42 A
4160Y/2400 42 A
4800 Delta 36 A
7200 Delta 24 A
12000 Delta 14 A
12470Y/7200 14 A
13200 Delta 13 A
13200Y/7620 13 A
13800 Delta 13 A
13800Y/7970 13 A
22900Y/13200 7.6 A
24940Y/14400 6.9 A
34500 Delta 5.0 A
34500Y/19920 5.0 A

Typical applications

  • Municipal and school facilities
  • Retail and restaurant service entrances
  • Small manufacturing and machine shops
  • EV charging installations
  • Office buildings and light commercial

Construction

Standard construction is aluminum windings in a sealed tank with mineral oil, ONAN cooled, 65 °C rise. The tank is welded and finished in Munsell Green 7GY3.29/1.5. A four-position no-load tap changer provides plus and minus two 2.5% full-capacity taps. Copper windings and natural ester fluid are available on request.

Standards and compliance

  • Built to ANSI/IEEE C57.12 and applicable NEMA standards
  • Meets DOE 2016 efficiency requirements
  • Factory test report supplied with every unit
  • Manufactured and supported by Bear Power Solutions, Brandon, Mississippi

Frequently asked questions

What voltages is the 300 kVA available in?

The 300 kVA is available with 15kV / 25kV / 35kV primary and 240V / 600V secondary. That is 105 configurations in total. Every voltage inside a class carries the same price and the same basic insulation level.

What is the lead time on a 300 kVA?

Lead times start at 10 weeks from order confirmation, depending on configuration and current factory loading. Non-standard voltages, accessories, custom enclosure work and non-standard fluid or winding material extend that. Confirm the delivery date with Bear Power Solutions before committing to a project schedule.

Is this a dead-front or live-front transformer?

Standard construction is dead-front with loadbreak elbow connections on the primary. Live-front construction is available on request and should be specified at the time of quotation.

Can the 300 kVA be supplied with copper windings or natural ester fluid?

Standard catalog construction is aluminum windings with mineral oil. Copper windings and natural ester fluid are available on request. Both affect price and lead time, so request a quotation for a non-standard build.

What standards does the 300 kVA meet?

Units are built to ANSI/IEEE C57.12 and applicable NEMA standards, and meet DOE 2016 efficiency requirements. Factory test reports are provided with every unit.

Sizing the 300 kVA

At its lowest available secondary voltage the 300 kVA draws 833 A at full load; at its highest it draws 289 A. That spread is what makes secondary voltage selection an installation-cost decision as much as an electrical one – the higher voltage cuts conductor size for the same delivered power.

Secondary current at this rating is high enough that parallel conductor runs or busway are normally required on the low-voltage side. Confirm the secondary termination arrangement and available bus space before ordering.

Request a quote

For a firm price on a 300 kVA in a specific voltage configuration, or for a non-standard build with copper windings, natural ester fluid or custom accessories, send the details below and Bear Power Solutions will respond with a written quotation.

Weeks: 0
How quick do you need this Transformer(s)?
Primary Voltage

12000 Delta, 12470Y/7200, 13200 Delta, 13200Y/7620, 13800 Delta, 13800Y/7970, 22900Y/13200, 2400 Delta, 24940Y/14400, 34500 Delta, 34500Y/19920, 4160 Delta, 4160Y/2400, 4800 Delta, 7200 Delta

Secondary Voltage

208Y/120, 240 Delta, 240/120 Delta, 415Y/240, 480 Delta, 480Y/277, 600Y/347

Shopping Cart

PLEASE CALL 601-912-3512 OR EMAIL SALES@BEARPOWERSOLUTIONS.COM TO VERIFY STOCK BEFORE SUBMITTING AN ORDER ON OIL FILLED TRANSFORMERS